主營產(chǎn)品:螺絲扭力測試儀|螺絲扭力檢測儀|螺絲破壞性測試儀|自攻螺絲測試儀|螺絲破裂測試儀|螺絲扭力試驗機|批頭扭力測試儀||螺帽扭斷力測試儀|批頭扭斷力測試儀|木螺絲扭力測試儀|機械螺絲測試儀-深圳-銷售●品牌: Nititoyo 擬基多友●名稱:螺絲扭力測試儀|螺絲扭力檢測儀●型號:NTY-M6 規(guī)格:M2-M6 ●型號:NTY-M10 規(guī)格:M2-M10●型號:NTY-M12 規(guī)格:M3-M12
Screw Counter | |
仠 Scorew Counter 丂ECT series | |
The number of screw bolting is setit checks whether a worker forget to tighten a screw! | |
ECT-02 Low pricea short form | |
The signal from an electric driver is counted. The bolting end signal from an electric driver is counted certainly. A check is easy with soundlight. A number check can be checked with a LCD display machinebuzzer sound. It is a malfunction check by the timer function. A screw can gnaw, idling detection can be performedonly normal screw bundle operation can be counted. Count cancellation function After the torque rise, if reverse rotation operation is performed immediately, the function in which the one number of counts returns is attached. (When the reverse signal is outputted from the driver) | |
ECT-03 丂Work丂sensor correspondence | |
The signal from an electric driver is counted.A check is easy with soundlight.It is a malfunction check by the timer function. Further Reliable management is possible at a work sensor function. It will become an error, if a work is removed before attaching the sensor which judges the existence of a workbecoming a bolting number. The apparatus of others [ a bolting completion signal ] is connectable. Since a signal will be outputted if it becomes Work O.K. or Count O.K. You can also use an automatic line. Work set timer function A worker''s safety can be consideredtime until a work is set and fixed to a fixed implement can be set up. Count cancellation function After the torque rise, if reverse rotation operation is performed immediately, the function in which the one number of counts returns is attached. (When the reverse signal is outputted from the driver) | |
ECT-05丂丂Work丂sensor correspondence | |
The signal from an electric driver is counted.A check is easy with soundlight.It is a malfunction check by the timer function. Further A brightlegible LED display Large-sized LED (a height of 26mm) is adopted as a display part. The check of a position to a dark place or the left number of counts becomes easy. Work sensor (a change is possible)/Completion signal/ Malfunction prevention function The peripheral equipmentconnection by the variegated function are possible. High-grade management is possible. Count cancellation function After the torque rise, if reverse rotation operation is performed immediately, the function in which the one number of counts returns is attached. (When the reverse signal is outputted from the driver) | |
It corresponds to various models by easy connection. To the electric driver out of which the screw bundle completion signal has come There is also a model which cannot be adapted.Moreover, in part, also when change of a setup is required, it is. Please ask to our company for details. It corresponds also to a torque wrench driver. In the torque wrench torque driver to which the torque rise signal output was attached, ECT-05 correspond with a changeover switch. ECT-02.03 set upcorrespond at the time of shipment. |
Specification | ECT-02 | ECT-03 | ECT-05 | ||
Display | LCD digital display | LED digital display | |||
The number of setting counts | 1-99 (count subtraction system) | ||||
Timer setup | LO TIME 0.0 - 2.0 seconds (between [ 0.01-0.09 ] 0.0-0.1) | LO TIME 0.0 - 2.0 seconds | |||
HI TIME 0.0 - 9.0 seconds | |||||
Auto clearance | 0.5 - 3.0 seconds (0.5-second interval) | ||||
Function | Counter,丂Timer setup,丂Count cancellation | ||||
Yes-no decision | O.K.: Buzzer sound / NG: Buzzer sound,LED red lighting incoming signal | ||||
Incoming signal | 亅 | Work sensor An open collector or a non-voltage input | Work sensor correspondence a change is possible) An open collector or a non-voltage input | ||
Output signal | 亅 | A screw bundle O.K. signal/ work O.K. signal Open collector output (Rated 30V.20mA) | O.K. signal A screw bundle NG signal / work NG signal Open collector output(Rated 30V.20mA) | ||
The contents of an output | 亅 | If a bolting number is become (display 00)a work is removed, you will be told about at "Work O.K." signala buzzer. | If it becomes a bolting number, you will be told about at "Work O.K." signala buzzer. Ais possible, when a work is removedit resets. | ||
Power supply | AC/DC adaptor DC4.2V | AC 100-120V (240V can be responded) | AC/DC adaptor DC7.5V | ||
Continuation use time | About 8 hours | - | |||
Auto-power-off | After the neglect during 90 minutes | - | |||
Size | 80乮H乯亊75乮W乯亊13乮D乯 | 108乮H乯亊77乮W乯亊40乮D乯 | 126乮H乯亊112乮W乯亊35乮D乯 | ||
Weight | (Abbreviation)100g | (Abbreviation)280g | (Abbreviation)400g | ||
Adaptation driver | Nitto Kohki: -- : by SP specification article Nakamura factory company of DLV7120/7130/7140/8120/8130/8140/8150 | ||||
Nakamura seisakusyo-- : by the SWP specification article high male company of 3K-110/120/180//9K-131/130/140/150 | |||||
HIOS -- : by the OPC specification article of VZ-1510/1820/3012/4506 | |||||
Etc. |